If you are facing one way audio issue with freeswitch for all outgoing calls via mobilink infinity trunk , all you need to do is to edit conf/vars.xml and set EXT_SIP_IP & EXT_RTP_IP to 192.168.100.1 . That’s it , your one way audio issue will be resolved :-) .